喷泉泵电机绕组烧坏故障的原因及处理喷泉泵烧坏或者绕组缘损坏会是漏电,非常危险,在通电的情况下切勿用手去触摸喷泉泵及管道等,以防触电,应立即切断电源,再处理。1、喷泉泵脱水运转,冷却恶化,应增加增加水位或者喷泉泵安装位置降低。2、电源电压过低,应调节变压器电压。3、喷泉泵电机绕组匝间,相间或对地短路,应该大修,更换绕组。4、电力电缆压降过大,应该更换大一规格的电缆线。5、喷泉泵起动过于频繁,应该按照说明书要求操作。6、水泵叶轮卡住,应该及时检查叶轮,清楚叶轮杂物。7、喷泉泵进口堵塞,应及时清理入口杂物及加过滤网。
The cause and treatment of motor winding burnout of fountain pump and its insulation damage are leakage and very dangerous. Do not touch the fountain pump and pipeline with your hands in case of electrification, in order to prevent electric shock, the power supply should be cut off immediately and dealt with again. 1. Fountain pump dehydration operation, cooling deterioration, should increase water level or reduce the installation position of fountain pump. 2. If the voltage of power supply is too low, the voltage of transformer should be adjusted. 3. The windings of motor of fountain pump should be overhauled and replaced if they are short-circuit to ground or turn to turn. 4. If the voltage drop of power cable is too large, it is necessary to replace the larger size cable. 5. Fountain pumps start too frequently and should be operated according to the instructions. 6. When the impeller of the pump is stuck, the impeller should be inspected in time and the impurities of the impeller should be clear. 7. Blockage of fountain pump inlet should be promptly cleaned up and filtered.